ELCOM SYSTEMS, INCORPORATED

RESISTIVE IMPEDANCE
TRANSFORMERS -
MINIMUM LOSS PADS
MODEL - RT50/75 &
MODEL - RT50/93





SPECIFICATIONS:                   RT50/75 IMPEDANCE TRANSFORMER    RT50/93 IMPEDANCE TRANSFORMER

FREQUENCY RANGE ..............    DC to 1500 MHz                   DC-1000 MHz

IMPEDANCE, INPUT TO OUTPUT....    50 to 75 OHMS                    50 to 93 OHMS

INSERTION LOSS(NOMINAL)*......    5.7 dB                           7.2 dB

ACCURACY .....................    DC to 1.0 GHz ± 0.5 dB           DC to 500 MHz ± 0.5 dB
                                  1.0 to 1.5 GHz ± 1.0 dB          0.5 to 1.0 GHz ± 1 dB

VSWR .........................    1.2:1 NOM., 1.35:1 at 1.5 GHz    1.2:1 NOM., 1.35:1 at 1 GHz

MAXIMUM POWER
 DISSIPATION AT 70 ° C ...        0.5 WATT CW, 1000 WATTS PEAK     0.5 WATT CW, 1000 WATTS PEAK

OPERATING TEMP. RANGE ........    -25 ° to +85 ° C                 -25 ° to +85 ° C
                                  (See Note 1)                     (See Note 1)

STORAGE TEMP. RANGE ..........    -55 ° to +125 ° C                -55 ° to +125 ° C

CONNECTORS ...................    BNC, TNC, N, SMA                 BNC, TNC, N, SMA

SIZE .........................    SEE PAGE 35                      SEE PAGE 35

AVAILABILITY .................    STOCK TO 30 DAYS ARO

ORDERING DATA ................    MODEL-IMP.(IN),SEX-IMP.(OUT),SEX/CONN.
                                  RT    50       M  -75        F  /BNC
Note 1:  USABLE -55 ° to
         +100 ° C.                  

 FABRICATED FROM MIL SPEC OR COMMERCIAL COMPONENTS.  SPECIALS AND BETWEEN SERIES UNITS ARE AVAILABLE, 
CONSULT FACTORY. ALL UNITS MATE WITH 50 OHM CONNECTORS, EXCEPT FOR TYPE N 75 OR 90 OHM END, WHICH
MATE WITH 75 OHM CONNECTORS.

* IL OF UNIT IS TESTED BY CONNECTING IT IN SERIES WITH A MATING UNIT, WITH HIGH IMPEDANCE ENDS
CONNECTED TOGETHER, THEN MEASURING THE SET FROM 50 OHM END TO 50 OHM END, AND USING HALF THE TOTAL
IL READING.