ELCOM SYSTEMS, INCORPORATED
RESISTIVE IMPEDANCE TRANSFORMERS -
MINIMUM LOSS PADS MODEL - RT50/75 & MODEL - RT50/93
|

 |
SPECIFICATIONS: RT50/75 IMPEDANCE TRANSFORMER RT50/93 IMPEDANCE TRANSFORMER
FREQUENCY RANGE .............. DC to 1500 MHz DC-1000 MHz
IMPEDANCE, INPUT TO OUTPUT.... 50 to 75 OHMS 50 to 93 OHMS
INSERTION LOSS(NOMINAL)*...... 5.7 dB 7.2 dB
ACCURACY ..................... DC to 1.0 GHz ± 0.5 dB DC to 500 MHz ± 0.5 dB
1.0 to 1.5 GHz ± 1.0 dB 0.5 to 1.0 GHz ± 1 dB
VSWR ......................... 1.2:1 NOM., 1.35:1 at 1.5 GHz 1.2:1 NOM., 1.35:1 at 1 GHz
MAXIMUM POWER
DISSIPATION AT 70 ° C ... 0.5 WATT CW, 1000 WATTS PEAK 0.5 WATT CW, 1000 WATTS PEAK
OPERATING TEMP. RANGE ........ -25 ° to +85 ° C -25 ° to +85 ° C
(See Note 1) (See Note 1)
STORAGE TEMP. RANGE .......... -55 ° to +125 ° C -55 ° to +125 ° C
CONNECTORS ................... BNC, TNC, N, SMA BNC, TNC, N, SMA
SIZE ......................... SEE PAGE 35 SEE PAGE 35
AVAILABILITY ................. STOCK TO 30 DAYS ARO
ORDERING DATA ................ MODEL-IMP.(IN),SEX-IMP.(OUT),SEX/CONN.
RT 50 M -75 F /BNC
Note 1: USABLE -55 ° to
+100 ° C.
FABRICATED FROM MIL SPEC OR COMMERCIAL COMPONENTS. SPECIALS AND BETWEEN SERIES UNITS ARE AVAILABLE,
CONSULT FACTORY. ALL UNITS MATE WITH 50 OHM CONNECTORS, EXCEPT FOR TYPE N 75 OR 90 OHM END, WHICH
MATE WITH 75 OHM CONNECTORS.
* IL OF UNIT IS TESTED BY CONNECTING IT IN SERIES WITH A MATING UNIT, WITH HIGH IMPEDANCE ENDS
CONNECTED TOGETHER, THEN MEASURING THE SET FROM 50 OHM END TO 50 OHM END, AND USING HALF THE TOTAL
IL READING.