ELCOM SYSTEMS, INCORPORATED

RESISTIVE DECOUPLER
MODEL - RD-1000

CAPICATIVE COUPLER
MODEL - CC-1000

INDUCTIVE DECOUPLER
MODEL - LD-R15 & 6R8





SPECIFICATIONS:                   RD-1000 RESISTIVE DECOUPLER

FREQUENCY RANGE ..............    DC to 1500 MHz
DC RESISTANCE ................    1000 OHMS
ACCURACY .....................    ± 5% at +25 ° C
MAXIMUM POWER
 DISSIPATION AT 70 ° C ...        0.5 WATT CW
PEAK VOLTAGE .................    250 VOLTS

                                  CC-1000 CAPACITIVE COUPLER

FREQUENCY RANGE ..............    20 to 1500 MHz
CAPACITANCE ..................    1000 PF
ACCURACY .....................    ± 20%    
MAXIMUM DC VOLTAGE ...........    500 VDC
INSERTION LOSS ...............    LESS THAN 1 dB AT 1500 MHz

                                  LD-R15 & 6R8 INDUCTIVE DECOUPLERS

MODEL ........................    LD-R15                LD-6R8
INDUCTANCE ...................    0.17 MICROHENRIES     6.0 MICROHENRIES
ACCURACY .....................    ± 25%                 ± 20%
MAXIMUM DC CURRENT............    2.5 AMPERES           0.5 AMPERES
MAXIMUM DC RESISTANCE ........    .03 OHMS              0.65 OHMS
MIN. RESONANT FREQUENCY ......    500 MHz               50 MHz

                                  SPECIFICATIONS COMMON TO ALL UNITS

SIZE .........................    SEE PAGE 35
CONNECTORS ...................    BNC, TNC, N, SMA, MALE to FEMALE
OPERATING TEMP. RANGE ........    -25 ° to +85 ° C (See Note 1)
STORAGE TEMP. RANGE ..........    -55 ° to +105 ° C

AVAILABILITY .................    STOCK TO 30 DAYS ARO

Note 1:  USABLE -55 ° to
         +100 ° C. .......        FABRICATED FROM MIL SPEC OR COMMERCIAL COMPONENTS.
                                  SPECIALS AVAILABLE, CONSULT FACTORY.