ELCOM SYSTEMS, INCORPORATED
MULTICOUPLER 2 & 4 PORT MODEL - TC-125-2 MODEL - TC-125-4
|

 |
SPECIFICATIONS: TC-125-2 MULTICOUPLER TC-125-4 MULTICOUPLER
NUMBER OF OUTPUT PORTS ....... 2 4
FREQUENCY RANGE .............. 1.5 to 125 MHz 1.5 to 125 MHz
IMPEDANCE .................... 50 OHMS 50 OHMS
VSWR ......................... 1.35:1 1.35:1
INSERTION LOSS ............... 1 dB OVER 3 dB 1 dB OVER 6 dB
POWER SPLIT POWER SPLIT
ISOLATION BETWEEN OUTPUTS .... 30 dB 30 dB 1.5 to 30 MHz
20 dB 30 to 125 MHz
OUTPUT BALANCE - LEVEL ....... .05 dB .1 dB 1.5 to 30 MHz
.2 db 30 to 125 MHz
OUTPUT BALANCE - PHASE ....... 1 DEGREE 2 DEGREES
MAX. INPUT POWER - UNMATCHED . 250 mW. 250 mW.
MAX. INPUT POWER - MATCHED ... 2 WATTS 2 WATTS
OPERATING TEMP. RANGE ........ -25 ° to +85 ° C (See Note 1)
CONNECTORS ................... BNC/F, TNC/F, N/F, SMA/F
SIZE ......................... SEE PAGE 33
AVAILABILITY ................. STOCK TO 30 DAYS ARO
ORDERING DATA ................ MODEL - CONN. TYPE
TC-125-2-BNC
Note 1: USABLE -55 ° to
+100 ° C. ....... FABRICATED FROM MIL SPEC OR COMMERCIAL COMPONENTS.
SPECIALS AVAILABLE, CONSULT FACTORY.